Shimadzu ELB300 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Wagi kuchenne Shimadzu ELB300. Shimadzu ELB300 Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 37
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
SHIMADZU ELECTRONIC BALANCE
EL SERIES
EL120, EL200, EL300, EL600,
EL1200, EL2000, EL3000, EL12K,
EL600S, EL6000S
INSTRUCTION MANUAL
M054-E109
TESTING & WEIGHING EQUIPMENT DIVISION
Przeglądanie stron 0
1 2 3 4 5 6 ... 36 37

Podsumowanie treści

Strona 1 - INSTRUCTION MANUAL

SHIMADZU ELECTRONIC BALANCEEL SERIESEL120, EL200, EL300, EL600,EL1200, EL2000, EL3000, EL12K,EL600S, EL6000SINSTRUCTION MANUALM054-E109TESTING &

Strona 2

- 5 -Observe thefollowing:Use only the AC adapter that is provided by thedistributor who is authorized by ShimadzuCorporation.Make sure that any forei

Strona 3 - Safety Precautions

- 6 -(7)The all segments illuminate forapproximately 6 seconds.is displayed.Press the [BREAK] key.Zero is displayed.The zero may be unstable immediate

Strona 4 - INTRODUCTION

- 7 -Procedure(1)Press the [MODE] key.The currently set conditions are displayed in symbols.(Example)The display changes in the order shown in the tab

Strona 5

- 8 -required for output. (Be acknowledged that measurementaccuracy may be sacrificed.)• Activating Zero Tracking ( ) will automatically cancelthe min

Strona 6

- 9 -6. Registration of UnitsThree units can be registered in addition to “gram”. The registered units remainafter the power has been turned off. Regi

Strona 7 - Key names and functions

- 10 -With nothing on the pan, go throughthe menu selections to display for calibration. (Refer to “5. MenuSelection”.)Press the [TARE] key.The value

Strona 8

- 11 -Zero flashes on the display.Remove the weight from the panand press the [TARE] key when thestability mark is displayed.appears on the display an

Strona 9

- 12 -Select piece counting mode (ConvPCS) in menu selection, and pressthe [TARE] key. (Refer to “5. MenuSelection”.)The number of reference pieces i

Strona 10 - • When using the AC adapter

- 13 -Place the container on the pan and press the [TARE] key.Select percentage conversion mode( %) in menu selection, andpress the [TARE] key. (Refer

Strona 11

- 14 -Procedure(1)increment, is displayedand the display reverts to the unitbefore menu selection.• Press the [BREAK] key to abortpiece counting setti

Strona 12

SHIMADZU ELECTRONIC BALANCEEL SERIESEL120, EL200, EL300, EL600, EL1200, EL2000, EL3000, EL12K,EL600S, EL6000SINSTRUCTION MANUALM054-E084TESTING &

Strona 13

- 15 -The internal values of the balance are beingrevised while is displayed. Do not turnoff the power while is displayed.Press the [TARE] key when

Strona 14 - →” is displayed for

- 16 -while the results are being displayed. (Continuous output isnot possible during specific gravity measurement.)• Return to step (3) by pressing t

Strona 15

- 17 -Preparationfor the [UNIT] key, the value will be calculated and displayedusing the latest reference.• The registered units remain after the powe

Strona 16 - • is displayed if an improper

- 18 -Both σx and σy should be within 1.5 times the standarddeviation indicated in “15. Specifications”.Load a weight of approximately 1/4th the weigh

Strona 17 - → 100 → 10

- 19 -Wipe any dirt away with a soft cloth moistenedwith a neutral detergent.Organic solvents and chemical dusters willdamage the coating and membrane

Strona 18

- 20 -When Phenomenon Cause and Solution• Affection of vibration or wind.⇒ Install the balance at a place withoutvibration or wind.⇒ Set the response

Strona 19

- 21 -15. SpecificationsModel EL120 EL200 EL300 EL600 EL1200Weighing capacity 120g 200g 300g 600g 1200gMinimum display 0.01g 0.01g 0.01g 0.05g 0.1gSta

Strona 20

- 22 -Model EL2000 EL3000 EL12K EL600S EL6000SWeighing capacity 2000g 3000g 12kg 600g 6000gMinimum display 0.1g 0.1g 1g 0.1g 1gStandard deviation σ ≤

Strona 21 - ―――――――――――――――――

- 23 -16. Parts ListProduct Name P/N RemarksBuilt-in battery 321-60063Below-balance weighing hook 321-34532-03 Cannot be used with the EL12K.Specific

Strona 22

- 24 -Caution andNotesWhen using the battery for the first time, orwhen using it after it has not been used for along period of time, recharge it befo

Strona 23

Follow the cautions below for safe and proper use of the EL balance.Do not use the EL balance in dangerous areas∗.Use only the AC adapter that is prov

Strona 24

- 25 -(3)Fix the sponge (14), battery (15), and holder plate (16) into thebattery compartment and fix them using the fixing screws (17).Ensure that bo

Strona 25

- 26 -Rechargingthe batterySet the power switch to “OFF”. Insert the AC adapter plug intothe power jack of the balance, and insert the AC adapter into

Strona 26 - 15. Specifications

- 27 -ConnectionAfter confirming that the power of the balance has been turnedoff, insert the plug of the IFB-102A into the DATA I/O connector ofthe b

Strona 27

- 28 -Command code + (CR) ⇒ See “18.4 Command Codes”.• When displaying the weightS −△△300.00g△ (CR)Unit + spaceSpace, number, decimal pointPolarity Po

Strona 28 - Special Accessories (Options)

- 29 -• Stop bit Select from 1 and 2.Set the baud rate to 1200 and the stop bit to 1when using the EP-60A.Press the [MODE] key to display(see “5. Menu

Strona 29 - Battery compartment

- 30 -(6)The currently selected parity is displayed with the stabilitymark.Select the desired parity and press the [TARE] key.∗ The data length become

Strona 30

- 31 -Command code Function DescriptionQ Start operation Switches the display from to weightwhen the power is turned on.Stops Auto Print and continuo

Strona 31 - Below-balance-weighing hook

TOKYO OFFICE3, Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, JapanPhone: 81(3)3219-5641 Fax: 81(3)3219-5710Cable Add.:SHIMADZU TOK

Strona 32

Thank you for purchasing the Shimadzu EL Series Electronic Balance. Beforeusing the balance, read this Instruction Manual carefully and store it for r

Strona 33

1. List of Components and Names of Units... 12. Installation ...

Strona 34 - → 1200 → 2400 → 4800 →9600

The following components (one for each) are contained in thepackage.- 1 -List ofcomponents1. List of Components and Names of UnitsBalance main unit AC

Strona 35 - → 2 → 1

- 2 -Key names and functionsUNIT keyBREAK keyMODE keyTARE keyName of Key FunctionBREAK 1) Changes the display from “oFF” to the weight.2) Discontinu

Strona 36

- 3 -DisplayAuto Print mark:Illuminates when the Auto Printfunction is turned on:Percentage markSpecific gravity measurement markNot applicable depend

Strona 37 - 4500-02200-600TD (368)

- 4 -Power suppyCheck the voltage.Check that the voltage of the power supply meetsthe voltage indicated on the AC adapter.Avoid the following conditio

Komentarze do niniejszej Instrukcji